If needed, insert a screwdriver into the lifting slot and pull upward. With the water turned off, you can manually lift the riser. (Do not rotate the screw too far counterclockwise or the nozzle or screw may come out). Turn the screw clockwise (into the stream of water) to decrease the distance or counterclockwise to increase the distance. Insert a screwdriver into the distance adjustment slot (Fig. The adjustment slot will stop turning when adjusted to the minimum spray pattern (40°). Adjust to any spray pattern between 40° and 360°.While holding the nozzle turret at the right stop, turn the screwdriver counterclockwise.The adjustment slot will stop turning when adjusted to the maximum spray pattern (360°).Adjust to any spray pattern between 40° and 360°.While holding the nozzle turret at the right stop turn the screwdriver clockwise.Insert a flat-head screwdriver into the pattern adjustment slot (Fig.(Rotate the turret to test the spray pattern.) The nozzle turret must be held in this position for all spray pattern adjustments. ![]() This is the fixed side of the spray pattern.